Harlequin Flexity sprung floor

Harlequin Flexity is a self-install sprung floor system featuring stained birch plywood panels and shock-dampening single density elastomer pads.

Performance surface: Harlequin Flexity can be used with a variety of performance surfaces. Harlequin have a range of performance vinyls and solid or engineered wood finishes to choose from. Ramps are available if required.

Installation: Harlequin Flexity is designed for permanent or semi-permanent installation. The panels join using a tongue and groove system and can be glued together for permanent installation or fixed using wood screws for a semi-permanent solution. The Harlequin Flexity panels are laid in such a way that cross joins do not coincide. This provides consistent shock dampening across the floor and offers the same feel and energy return to one or several dancers.

 Permanent or Portable Permanent or Semi-permanent
Panel Size

Dance Surface Area

1.125m x 2.250m

1.089m x 2.214m

Minimum Floor Thickness (before inclusion of chosen surface) 37mm
Weight 11.85kg/m² (Without surface)
Testing Standard

Shock Absorption

Vertical Deformation

Area Deflection

Rolling Load

BS EN 14904:2006

67%

3.9mm

12.8%

>1500 N

Testing Standard

Point Load

Uniform Distribution Load

BS EN 1991-1-1:2002

>3.60kN

>10.00kN

Fire Rating Bfls 1 to EN 13501
Impact Sound Reduction 104.20 dB
Thermal Resistance – R Value 1.52 m²K/W
Thermal Insulation – U Value 0.658 W/m²K
Category of Use A4
VOC Emissions <0.10 mg/m³
Warranty 10 years
Installation Installed by Harlequin or by the customer
Underfloor Heating Suitable for use with

underfloor heating

Applications

Harlequin Flexity can be used in conjunction with the following surface finishes:

Specifications
+ -
 Permanent or Portable Permanent or Semi-permanent
Panel Size

Dance Surface Area

1.125m x 2.250m

1.089m x 2.214m

Minimum Floor Thickness (before inclusion of chosen surface) 37mm
Weight 11.85kg/m² (Without surface)
Testing Standard

Shock Absorption

Vertical Deformation

Area Deflection

Rolling Load

BS EN 14904:2006

67%

3.9mm

12.8%

>1500 N

Testing Standard

Point Load

Uniform Distribution Load

BS EN 1991-1-1:2002

>3.60kN

>10.00kN

Fire Rating Bfls 1 to EN 13501
Impact Sound Reduction 104.20 dB
Thermal Resistance – R Value 1.52 m²K/W
Thermal Insulation – U Value 0.658 W/m²K
Category of Use A4
VOC Emissions <0.10 mg/m³
Warranty 10 years
Installation Installed by Harlequin or by the customer
Underfloor Heating Suitable for use with

underfloor heating

Related Products
+ -

Applications

Harlequin Flexity can be used in conjunction with the following surface finishes:

Who performs on Harlequin Flexity

Request a Quote

Please complete your details and one of our team will be in touch. If you prefer to speak to someone, please call us on +852 254 11 666. Please complete all form fields marked with an asterisk.

Harlequin Asia respects the information we hold on you and we take the security of your information very seriously. Our Privacy Statement (available on our website) gives you more information about the data we hold on you, what we do with that data, with whom we share your data and your rights under data protection law.